CDZNS - EUTROLOY 16300 LC
- MSDS: CDZNS
- Manufacturer: EUTECTIC CORP
- Product Name: EUTROLOY 16300 LC
- National Stock Number: 3439-00N065149
Product Identification
Product ID:EUTROLOY 16300 LC
MSDS Date:11/01/1992
FSC:3439
NIIN:00N065149
MSDS Number: CDZNS
Responsible Party
FLUSHING, NY 11358-2799
US
Emergency Phone: 718-358-4000
Info Phone: 718-358-4000
Cage: 72271
Contractor
Telephone: 704-527-9800/ 800-221-1433
Cage: 72271
Ingredients
IRON
CAS: 7439-89-6
RTECS: NO4565500
Fraction By Weight: 10-20%
OSHA PEL N/K
ACGIH TLV: N/K
CHROMIUM (SARA 313) (CERCLA)
CAS: 7440-47-3
RTECS: GB4200000
Fraction By Weight: 10-20%
OSHA PEL 1 MG/M3
ACGIH TLV: 0.5 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
NICKEL (SARA 313) (CERCLA)
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: 10-20%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3
MOLYBDENUM
CAS: 7439-98-7
RTECS: QA4680000
OSHA PEL 10 PPM
ACGIH TLV: 10 PPM
MANGANESE (SARA 313)
CAS: 7439-96-5
RTECS: OO9275000
Fraction By Weight: 1-5%
OSHA PEL C 5 MG/M3 DUST
ACGIH TLV: 5 MG/M3 DUST
SIDEROSIS WHICH MAY ALSO AFFECT PULM FUNC. LUNGS
RTECS: 9999999ZZ
OVEREXP MAY CAUSE METAL FUME FEVER W/CHILLS, FEVER,
RTECS: 9999999ZZ
EXCESS OVEREXP MAY AFFECT CNS W/MUSC WEAK & TREMORS.
RTECS: 9999999ZZ
APPEAR. WORKERS EXPOSED TO MANGANESE CMPDS SHOULD
RTECS: 9999999ZZ
OVEREXP TO MOLYBDENUM
RTECS: 9999999ZZ
INGEST/IN CONT W/EYES. MOLYBDENUM TRIOXIDE HAS
RTECS: 9999999ZZ
DISTURB IN ANIMALS. LONG TERM EFTS NOT KNOWN.
RTECS: 9999999ZZ
METALLIC TASTE, NAUS, TIGHTNESS OF CHEST,
RTECS: 9999999ZZ
ALLERGIC RXNS. LONG TERM OVEREXP MAY CAUSE LUNG
RTECS: 9999999ZZ
WORKERS INDICATE HIGHER INCIDENCE OF LUNG & NASAL
RTECS: 9999999ZZ
CAUSE IRRIT OF RESP SYS, LUNG DMG & ASTHMA TYPE
RTECS: 9999999ZZ
RADIA, SPKS & ELEC SHOCK. AT MIN, THIS
RTECS: 9999999ZZ
PROTECTORS, APRONS, HATS AS WELL AS DARK, PROT
RTECS: 9999999ZZ
INSULATE THEMSELVES FROM WORK AND ELECTRICAL
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: FUMES, GASES & DUSTS CAN BE
DANGEROUS TO YOUR HLTH. CERTAIN MED STUDIES SUGGEST LUNG DMG CAN
RSLT FROM OVEREXP TO FUMES. SHORT TERM OVEREXP CAN RSLT IN DIZZ,
NAUS/DRYNESS/IRRIT OF NOSE, THROAT/ EYES. EXCESS OVEREXP CAN CAUSE
BRONCH ASTHMA, LUNG FIBROSIS, PNEUMOCONIOSIS/SIDEROSIS (IRON
DEPOSITS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NICKEL: IARC MONO ON EVAL OF CARCIN RISK
OF CHEMS TO MAN, VOL 49, PG 257, 1990: GROUP 2B. NTP 7TH ANNUAL RPT
(SUP DAT)
Effects of Overexposure:HLTH HAZ: IN LUNG). METAL FUME FEVER CAN BE
CAUSED BY INHAL OF CERTAIN METALLIC CMPDS DURING WELDING, GRINDING,
BRAZING, SOLDERING/CUTTING. SYMPS ARE SIMILAR TO INFLUENZA TYPE
SICKNESS INCL CHILLS, FE VER, HEAD & MUSC ACHE, TIGHTNESS OF CHEST,
DRYNESS OF NOSE & MOUTH, MUSC WEAK, NAUS & VOMIT. SYMPS USUALLY
(SUP DAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL: MOVE TO FRESH AIR. CONTACT MD & ADVISE OF INGREDIENTS.
SKIN: THOROUGHLY WASH AFFECTED AREAS W/SOAP & WATER TO REMOVE ALL
RESIDUE. IF IRRITATION/BURNS DEVELOP, CONSULT MD. EYES: THOROUGHLY
FLUSH W/WATER FOR AT LEAST 15 MINUTES TO REMOVE ALL RESIDUE.
OBTAIN MED ADVISE FOR FLUXES & CHEMICAL AIDS. ADVISE MD OF
INGREDIENTS. INGEST: CALL MD AND/LOC POISON CTL CENTER. ADVISE OF
INGREDIENTS.
Fire Fighting
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL FOAM TYPE.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:SOME FLUXES & CHEMICAL AIDS MAY GIVE OFF
HYDROGEN CHLORIDE, PHOSGENE & CHLORINE GASES. CANS, UNDER PRESS &
FLAM, MAY EXPLODE. FOR MORE INFO CONT NEHC .
Accidental Release
Spill Release Procedures:NONE SPECIFIED BY MANUFACTURER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:PLEASE READ AND UNDERSTAND THE PRODUCT
LABEL INFORMATION FOR PROPER PROCEDURES AND USE.
Other Precautions:SEE ANSI Z49.1 "SFTY IN WELDING & CUTTING" & CHAPTER
II OF "THERMAL SPRAYING", PUBLISHED BY AMERICAN WELDING SOCIETY &
OSHA PUBLICATION 2206 (29 CFR) FOR MORE DETAILS. TRAIN WELDER TO
KEEP HIS/HER FAC E AWAY FROM FUME/DUST PLUME.
Exposure Controls
Respiratory Protection:IF THE WORK STATION IS NOT PROPERLY VENTILATED
TO EXHAUST ALL FUMES, VAPORS AND DUSTS BELOW THE RECOMMENDED
EXPOSURE LIMITS, USE A NIOSH APPROVED RESPIRATOR.
Ventilation:USE ENOUGH GEN VENT & LOC EXHST AT WORK SITE TO KEEP ALL
FUMES & DUSTS FROM WORKER'S BRTHG ZONE & GEN AREA.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
WEAR HAND, HEAD & BODY PROT WHICH HELP TO PVNT INJURY FROM (ING 17)
Work Hygienic Practices:TO PREVENT CONTACT ALLERGIES, WASH HANDS AND
CHANGE CLOTHES AFTER USE.
Supplemental Safety and Health
EXPLAN OF CARCIN: ON CARCINS, 1994: ANTIC TO BE CARCIN. HUMAN: LUNGS.
EFTS OF OVEREXP: OCCUR W/IN SEVERAL HRS AFTER OVEREXP & MAY LAST
8-24 HRS. CONSULT MD IMMED IF ANY OF THESE SYMPS DEVELOP AFTER WE
LDING OPERATION. IRON: OVEREXP MAY LEADTO GEN IRRIT OF RESP TRACT.
IF INHALED, LONG-TERM OVEREXP MAY CAUSE (ING 6)
Chemical Properties
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OZONE, CARBON MONOXIDE & DIOXIDE,
NITROGEN OXIDES, CERTAIN INERT GASES. FOR MORE SPECIFIC INFO CONT
NEHC .
Disposal
Waste Disposal Methods:DISPOSE OF WASTE MATERIAL, POWDERS, GRINDING OR
FILTER RESIDUES IN AN ENVIRONMENTALLY SENSITIVE MANNER I/A/W FED,
STATE & LOC REGS. USE APPROP MEASURES TO KEEP AIRBORNE DUST LEVELS
CONTAINED I/A/W EXP OS LEVELS OF INGS SECTION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.